Eaton 15BJ160CA Transient Voltage Suppressor 160 V
Eaton 15BJ160CA Transient Voltage Suppressor 160 V

Eaton 15BJ160CA Transient Voltage Suppressor 160 V

Share
15BJ160CA: transient voltage suppressor diode, 160 V standoff, 259 V clamp, 5.8 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton 15BJ160CA Transient Voltage Suppressor 160 V

    15BJ160CA at a glance: transient voltage suppressor diode, 160 V standoff, 259 V clamp, 5.8 A pulse, 1500 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part number15BJ160CA
    Standoff voltage (VR)160 V
    Leakage current at VR1 uA
    Breakdown voltage at IT178 V to 197 V
    Test current (IT)1 mA
    Clamping voltage at IPP259 V
    Peak pulse current5.8 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11206

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11206; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.67 percent, from 178 V to 197 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 160 V standing the leakage is at most 1 uA, so the part draws 0.16 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 76 of 92 in the Eaton catalogue.

    Series Positioning

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd