Eaton 15BJ16CA Transient Voltage Suppressor 16 V
Eaton 15BJ16CA Transient Voltage Suppressor 16 V

Eaton 15BJ16CA Transient Voltage Suppressor 16 V

Share
15BJ16CA: transient voltage suppressor diode, 16 V standoff, 26 V clamp, 57.7 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton 15BJ16CA Transient Voltage Suppressor 16 V

    15BJ16CA at a glance: transient voltage suppressor diode, 16 V standoff, 26 V clamp, 57.7 A pulse, 1500 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part number15BJ16CA
    Standoff voltage (VR)16 V
    Leakage current at VR1 uA
    Breakdown voltage at IT17.8 V to 19.7 V
    Test current (IT)1 mA
    Clamping voltage at IPP26 V
    Peak pulse current57.7 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11206

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11206; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.67 percent, from 17.8 V to 19.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 16 V standing the leakage is at most 1 uA, so the part draws 0.016 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 21 of 92 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd