Eaton 15BJ17AH 17 V 1500 W TVS Diode
Eaton 15BJ17AH 17 V 1500 W TVS Diode

Eaton 15BJ17AH 17 V 1500 W TVS Diode

Share
15BJ17AH: transient voltage suppressor diode, 17 V standoff, 27.6 V clamp, 54.4 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton 15BJ17AH 17 V 1500 W TVS Diode

    15BJ17AH at a glance: transient voltage suppressor diode, 17 V standoff, 27.6 V clamp, 54.4 A pulse, 1500 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part number15BJ17AH
    Standoff voltage (VR)17 V
    Leakage current at VR1 uA
    Breakdown voltage at IT18.9 V to 20.9 V
    Test current (IT)1 mA
    Clamping voltage at IPP27.6 V
    Peak pulse current54.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1059

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1059; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.58 percent, from 18.9 V to 20.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 17 V standing the leakage is at most 1 uA, so the part draws 0.017 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 24 of 92 in the Eaton catalogue.

    Series Positioning

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Shenzhen Gaorunxin Technology Co., Ltd