Eaton 15BJ180CA Transient Voltage Suppressor 180 V
Eaton 15BJ180CA Transient Voltage Suppressor 180 V

Eaton 15BJ180CA Transient Voltage Suppressor 180 V

Share
15BJ180CA: transient voltage suppressor diode, 180 V standoff, 292 V clamp, 5.2 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton 15BJ180CA Transient Voltage Suppressor 180 V

    15BJ180CA at a glance: transient voltage suppressor diode, 180 V standoff, 292 V clamp, 5.2 A pulse, 1500 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part number15BJ180CA
    Standoff voltage (VR)180 V
    Leakage current at VR1 uA
    Breakdown voltage at IT201 V to 222 V
    Test current (IT)1 mA
    Clamping voltage at IPP292 V
    Peak pulse current5.2 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11206

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11206; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.45 percent, from 201 V to 222 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 180 V standing the leakage is at most 1 uA, so the part draws 0.18 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 80 of 92 in the Eaton catalogue.

    Positioning in the Range

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products