Eaton 15BJ400A 400 V 1500 W TVS Diode
Eaton 15BJ400A 400 V 1500 W TVS Diode

Eaton 15BJ400A 400 V 1500 W TVS Diode

Share
15BJ400A: transient voltage suppressor diode, 400 V standoff, 648 V clamp, 2.3 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton 15BJ400A 400 V 1500 W TVS Diode

    15BJ400A at a glance: transient voltage suppressor diode, 400 V standoff, 648 V clamp, 2.3 A pulse, 1500 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number15BJ400A
    Standoff voltage (VR)400 V
    Leakage current at VR1 uA
    Breakdown voltage at IT447 V to 494 V
    Test current (IT)1 mA
    Clamping voltage at IPP648 V
    Peak pulse current2.3 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11206

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11206; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.51 percent, from 447 V to 494 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 400 V standing the leakage is at most 1 uA, so the part draws 0.4 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 91 of 92 in the Eaton catalogue.

    Positioning in the Range

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.