Eaton 15BJ440A 440 V 1500 W TVS Diode
Eaton 15BJ440A 440 V 1500 W TVS Diode

Eaton 15BJ440A 440 V 1500 W TVS Diode

Share
15BJ440A: transient voltage suppressor diode, 440 V standoff, 713 V clamp, 2.1 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton 15BJ440A 440 V 1500 W TVS Diode

    15BJ440A at a glance: transient voltage suppressor diode, 440 V standoff, 713 V clamp, 2.1 A pulse, 1500 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part number15BJ440A
    Standoff voltage (VR)440 V
    Leakage current at VR1 uA
    Breakdown voltage at IT492 V to 543 V
    Test current (IT)1 mA
    Clamping voltage at IPP713 V
    Peak pulse current2.1 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11206

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11206; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.37 percent, from 492 V to 543 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 440 V standing the leakage is at most 1 uA, so the part draws 0.44 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 92 of 92 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd