15BJ48CAH: transient voltage suppressor diode, 48 V standoff, 77.4 V clamp, 19.4 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton 15BJ48CAH Transient Voltage Suppressor 48 V

    15BJ48CAH at a glance: transient voltage suppressor diode, 48 V standoff, 77.4 V clamp, 19.4 A pulse, 1500 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part number15BJ48CAH
    Standoff voltage (VR)48 V
    Leakage current at VR1 uA
    Breakdown voltage at IT53.3 V to 58.9 V
    Test current (IT)1 mA
    Clamping voltage at IPP77.4 V
    Peak pulse current19.4 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1059

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1059; the package line above is the
    body the part is built in.

    How to Read These Ratings

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.51 percent, from 53.3 V to 58.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 48 V standing the leakage is at most 1 uA, so the part draws 0.048 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 50 of 92 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.