| Parameter | Value |
|---|---|
| Orderable part number | 15BJ51AH |
| Standoff voltage (VR) | 51 V |
| Leakage current at VR | 1 uA |
| Breakdown voltage at IT | 56.7 V to 62.7 V |
| Test current (IT) | 1 mA |
| Clamping voltage at IPP | 82.4 V |
| Peak pulse current | 18.2 A |
| Polarity | Unidirectional |
| Peak pulse power, 10/1000 us | 1500 W |
| Package | SMB (DO-214AA) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1059 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data ELX1059; the package line above is the
body the part is built in.
The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.
The breakdown window spans 10.58 percent, from 56.7 V to 62.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 51 V standing the leakage is at most 1 uA, so the part draws 0.051 mW on the rail. Small, but it is the number that matters on a battery input.
Within the 15BJ family this is item 52 of 92 in the Eaton catalogue.
The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.
How much capacitance does it add?
Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.
How do I pick the standoff voltage?
Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.