Eaton 15BJ58CA TVS Diode, 93.6 V Clamp
Eaton 15BJ58CA TVS Diode, 93.6 V Clamp

Eaton 15BJ58CA TVS Diode, 93.6 V Clamp

Share
15BJ58CA: transient voltage suppressor diode, 58 V standoff, 93.6 V clamp, 16.1 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton 15BJ58CA TVS Diode, 93.6 V Clamp

    15BJ58CA at a glance: transient voltage suppressor diode, 58 V standoff, 93.6 V clamp, 16.1 A pulse, 1500 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number15BJ58CA
    Standoff voltage (VR)58 V
    Leakage current at VR1 uA
    Breakdown voltage at IT64.4 V to 71.2 V
    Test current (IT)1 mA
    Clamping voltage at IPP93.6 V
    Peak pulse current16.1 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11206

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11206; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.56 percent, from 64.4 V to 71.2 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 58 V standing the leakage is at most 1 uA, so the part draws 0.058 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 55 of 92 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products