Eaton 15BJ6.0CA TVS Diode, 10.3 V Clamp
Eaton 15BJ6.0CA TVS Diode, 10.3 V Clamp

Eaton 15BJ6.0CA TVS Diode, 10.3 V Clamp

Share
15BJ6.0CA: transient voltage suppressor diode, 6 V standoff, 10.3 V clamp, 145.6 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton 15BJ6.0CA TVS Diode, 10.3 V Clamp

    15BJ6.0CA at a glance: transient voltage suppressor diode, 6 V standoff, 10.3 V clamp, 145.6 A pulse, 1500 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number15BJ6.0CA
    Standoff voltage (VR)6 V
    Leakage current at VR250 uA
    Breakdown voltage at IT6.67 V to 7.37 V
    Test current (IT)10 mA
    Clamping voltage at IPP10.3 V
    Peak pulse current145.6 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11206

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11206; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.49 percent, from 6.67 V to 7.37 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 6 V standing the leakage is at most 250 uA, so the part draws 1.5 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 2 of 92 in the Eaton catalogue.

    Positioning in the Range

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.