Eaton 15BJ64CAH Transient Voltage Suppressor 64 V
Eaton 15BJ64CAH Transient Voltage Suppressor 64 V

Eaton 15BJ64CAH Transient Voltage Suppressor 64 V

Share
15BJ64CAH: transient voltage suppressor diode, 64 V standoff, 103 V clamp, 14.6 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton 15BJ64CAH Transient Voltage Suppressor 64 V

    15BJ64CAH at a glance: transient voltage suppressor diode, 64 V standoff, 103 V clamp, 14.6 A pulse, 1500 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part number15BJ64CAH
    Standoff voltage (VR)64 V
    Leakage current at VR1 uA
    Breakdown voltage at IT71.1 V to 78.6 V
    Test current (IT)1 mA
    Clamping voltage at IPP103 V
    Peak pulse current14.6 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1059

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1059; the package line above is the
    body the part is built in.

    How to Read These Ratings

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.55 percent, from 71.1 V to 78.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 64 V standing the leakage is at most 1 uA, so the part draws 0.064 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 59 of 92 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.