Eaton 15BJ75A 75 V 1500 W TVS Diode
Eaton 15BJ75A 75 V 1500 W TVS Diode

Eaton 15BJ75A 75 V 1500 W TVS Diode

Share
15BJ75A: transient voltage suppressor diode, 75 V standoff, 121 V clamp, 12.4 A pulse, 1500 W, unidirectional.
    • Product Details
    • Download

    Eaton 15BJ75A 75 V 1500 W TVS Diode

    15BJ75A at a glance: transient voltage suppressor diode, 75 V standoff, 121 V clamp, 12.4 A pulse, 1500 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number15BJ75A
    Standoff voltage (VR)75 V
    Leakage current at VR1 uA
    Breakdown voltage at IT83.3 V to 92.1 V
    Test current (IT)1 mA
    Clamping voltage at IPP121 V
    Peak pulse current12.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11206

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11206; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.56 percent, from 83.3 V to 92.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 75 V standing the leakage is at most 1 uA, so the part draws 0.075 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 61 of 92 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products