15BJ8.5CA: transient voltage suppressor diode, 8.5 V standoff, 14.4 V clamp, 104.2 A pulse, 1500 W, bidirectional.
    • Product Details
    • Download

    Eaton 15BJ8.5CA Transient Voltage Suppressor 8.5 V

    15BJ8.5CA at a glance: transient voltage suppressor diode, 8.5 V standoff, 14.4 V clamp, 104.2 A pulse, 1500 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part number15BJ8.5CA
    Standoff voltage (VR)8.5 V
    Leakage current at VR20 uA
    Breakdown voltage at IT9.44 V to 10.4 V
    Test current (IT)1 mA
    Clamping voltage at IPP14.4 V
    Peak pulse current104.2 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us1500 W
    PackageSMB (DO-214AA)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11206

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11206; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.17 percent, from 9.44 V to 10.4 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 8.5 V standing the leakage is at most 20 uA, so the part draws 0.17 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15BJ family this is item 7 of 92 in the Eaton catalogue.

    What This Family Is For

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.