| Parameter | Value |
|---|---|
| Orderable part number | 15BJ90CA |
| Standoff voltage (VR) | 90 V |
| Leakage current at VR | 1 uA |
| Breakdown voltage at IT | 100 V to 111 V |
| Test current (IT) | 1 mA |
| Clamping voltage at IPP | 146 V |
| Peak pulse current | 10.3 A |
| Polarity | Bidirectional |
| Peak pulse power, 10/1000 us | 1500 W |
| Package | SMB (DO-214AA) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11206 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11206; the package line above is the
body the part is built in.
A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.
The breakdown window spans 11 percent, from 100 V to 111 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 90 V standing the leakage is at most 1 uA, so the part draws 0.09 mW on the rail. Small, but it is the number that matters on a battery input.
Within the 15BJ family this is item 65 of 92 in the Eaton catalogue.
Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.
How do I pick the standoff voltage?
Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd