15KP100CA: transient voltage suppressor diode, 100 V standoff, 161.3 V clamp, 93.6 A pulse, 15000 W, bidirectional.
    • Product Details
    • Download

    Eaton 15KP100CA Transient Voltage Suppressor 100 V

    15KP100CA at a glance: transient voltage suppressor diode, 100 V standoff, 161.3 V clamp, 93.6 A pulse, 15000 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number15KP100CA
    Standoff voltage (VR)100 V
    Leakage current at VR2 uA
    Breakdown voltage at IT111 V to 123 V
    Test current (IT)5 mA
    Clamping voltage at IPP161.3 V
    Peak pulse current93.6 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.81 percent, from 111 V to 123 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 100 V standing the leakage is at most 2 uA, so the part draws 0.2 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 25 of 37 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.