Eaton 15KP150A Unidirectional TVS Diode P600 axial
Eaton 15KP150A Unidirectional TVS Diode P600 axial

Eaton 15KP150A Unidirectional TVS Diode P600 axial

Share
15KP150A: transient voltage suppressor diode, 150 V standoff, 241.9 V clamp, 62.4 A pulse, 15000 W, unidirectional.
    • Product Details
    • Download

    Eaton 15KP150A Unidirectional TVS Diode P600 axial

    15KP150A at a glance: transient voltage suppressor diode, 150 V standoff, 241.9 V clamp, 62.4 A pulse, 15000 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number15KP150A
    Standoff voltage (VR)150 V
    Leakage current at VR2 uA
    Breakdown voltage at IT167 V to 185 V
    Test current (IT)5 mA
    Clamping voltage at IPP241.9 V
    Peak pulse current62.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    What the Numbers Mean

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.78 percent, from 167 V to 185 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 150 V standing the leakage is at most 2 uA, so the part draws 0.3 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 29 of 37 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.