Eaton 15KP160A 160 V 15000 W TVS Diode
Eaton 15KP160A 160 V 15000 W TVS Diode

Eaton 15KP160A 160 V 15000 W TVS Diode

Share
15KP160A: transient voltage suppressor diode, 160 V standoff, 258.6 V clamp, 58.4 A pulse, 15000 W, unidirectional.
    • Product Details
    • Download

    Eaton 15KP160A 160 V 15000 W TVS Diode

    15KP160A at a glance: transient voltage suppressor diode, 160 V standoff, 258.6 V clamp, 58.4 A pulse, 15000 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number15KP160A
    Standoff voltage (VR)160 V
    Leakage current at VR2 uA
    Breakdown voltage at IT178 V to 197 V
    Test current (IT)5 mA
    Clamping voltage at IPP258.6 V
    Peak pulse current58.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    The Figures Explained

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.67 percent, from 178 V to 197 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 160 V standing the leakage is at most 2 uA, so the part draws 0.32 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 30 of 37 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.