Eaton 15KP160CA TVS Diode, 258.6 V Clamp
Eaton 15KP160CA TVS Diode, 258.6 V Clamp

Eaton 15KP160CA TVS Diode, 258.6 V Clamp

Share
15KP160CA: transient voltage suppressor diode, 160 V standoff, 258.6 V clamp, 58.4 A pulse, 15000 W, bidirectional.
    • Product Details
    • Download

    Eaton 15KP160CA TVS Diode, 258.6 V Clamp

    15KP160CA at a glance: transient voltage suppressor diode, 160 V standoff, 258.6 V clamp, 58.4 A pulse, 15000 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part number15KP160CA
    Standoff voltage (VR)160 V
    Leakage current at VR2 uA
    Breakdown voltage at IT178 V to 197 V
    Test current (IT)5 mA
    Clamping voltage at IPP258.6 V
    Peak pulse current58.4 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.67 percent, from 178 V to 197 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 160 V standing the leakage is at most 2 uA, so the part draws 0.32 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 30 of 37 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Shenzhen Gaorunxin Technology Co., Ltd