Eaton 15KP17A Unidirectional TVS Diode P600 axial
Eaton 15KP17A Unidirectional TVS Diode P600 axial

Eaton 15KP17A Unidirectional TVS Diode P600 axial

Share
15KP17A: transient voltage suppressor diode, 17 V standoff, 29.3 V clamp, 515.4 A pulse, 15000 W, unidirectional.
    • Product Details
    • Download

    Eaton 15KP17A Unidirectional TVS Diode P600 axial

    15KP17A at a glance: transient voltage suppressor diode, 17 V standoff, 29.3 V clamp, 515.4 A pulse, 15000 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part number15KP17A
    Standoff voltage (VR)17 V
    Leakage current at VR5000 uA
    Breakdown voltage at IT18.9 V to 20.9 V
    Test current (IT)50 mA
    Clamping voltage at IPP29.3 V
    Peak pulse current515.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.58 percent, from 18.9 V to 20.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 17 V standing the leakage is at most 5000 uA, so the part draws 85 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 1 of 37 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.