Eaton 15KP180CA TVS Diode, 288.5 V Clamp
Eaton 15KP180CA TVS Diode, 288.5 V Clamp

Eaton 15KP180CA TVS Diode, 288.5 V Clamp

Share
15KP180CA: transient voltage suppressor diode, 180 V standoff, 288.5 V clamp, 52.3 A pulse, 15000 W, bidirectional.
    • Product Details
    • Download

    Eaton 15KP180CA TVS Diode, 288.5 V Clamp

    15KP180CA at a glance: transient voltage suppressor diode, 180 V standoff, 288.5 V clamp, 52.3 A pulse, 15000 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part number15KP180CA
    Standoff voltage (VR)180 V
    Leakage current at VR2 uA
    Breakdown voltage at IT201 V to 222 V
    Test current (IT)5 mA
    Clamping voltage at IPP288.5 V
    Peak pulse current52.3 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.45 percent, from 201 V to 222 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 180 V standing the leakage is at most 2 uA, so the part draws 0.36 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 32 of 37 in the Eaton catalogue.

    Positioning in the Range

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products