| Parameter | Value |
|---|---|
| Orderable part number | 15KP18CA |
| Standoff voltage (VR) | 18 V |
| Leakage current at VR | 5000 uA |
| Breakdown voltage at IT | 20 V to 22.1 V |
| Test current (IT) | 50 mA |
| Clamping voltage at IPP | 30.9 V |
| Peak pulse current | 488.7 A |
| Polarity | Bidirectional |
| Peak pulse power, 10/1000 us | 15000 W |
| Package | P600 axial |
| Mounting | Through-hole |
| Operating temperature | -55 °C to +175 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11207 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11207; the package line above is the
body the part is built in.
A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.
The breakdown window spans 10.5 percent, from 20 V to 22.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 18 V standing the leakage is at most 5000 uA, so the part draws 90 mW on the rail. Small, but it is the number that matters on a battery input.
Within the 15KPE family this is item 2 of 37 in the Eaton catalogue.
Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.
Why is the clamp voltage higher than the breakdown voltage?
The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.