| Parameter | Value |
|---|---|
| Orderable part number | 15KP20A |
| Standoff voltage (VR) | 20 V |
| Leakage current at VR | 1500 uA |
| Breakdown voltage at IT | 22.2 V to 24.5 V |
| Test current (IT) | 20 mA |
| Clamping voltage at IPP | 34.3 V |
| Peak pulse current | 440.2 A |
| Polarity | Unidirectional |
| Peak pulse power, 10/1000 us | 15000 W |
| Package | P600 axial |
| Mounting | Through-hole |
| Operating temperature | -55 °C to +175 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11207 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11207; the package line above is the
body the part is built in.
A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.
The breakdown window spans 10.36 percent, from 22.2 V to 24.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 20 V standing the leakage is at most 1500 uA, so the part draws 30 mW on the rail. Small, but it is the number that matters on a battery input.
Within the 15KPE family this is item 3 of 37 in the Eaton catalogue.
The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.
How do I pick the standoff voltage?
Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.