Eaton 15KP20CA Transient Voltage Suppressor 20 V
Eaton 15KP20CA Transient Voltage Suppressor 20 V

Eaton 15KP20CA Transient Voltage Suppressor 20 V

Share
15KP20CA: transient voltage suppressor diode, 20 V standoff, 34.3 V clamp, 440.2 A pulse, 15000 W, bidirectional.
    • Product Details
    • Download

    Eaton 15KP20CA Transient Voltage Suppressor 20 V

    15KP20CA at a glance: transient voltage suppressor diode, 20 V standoff, 34.3 V clamp, 440.2 A pulse, 15000 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part number15KP20CA
    Standoff voltage (VR)20 V
    Leakage current at VR1500 uA
    Breakdown voltage at IT22.2 V to 24.5 V
    Test current (IT)20 mA
    Clamping voltage at IPP34.3 V
    Peak pulse current440.2 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.36 percent, from 22.2 V to 24.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 20 V standing the leakage is at most 1500 uA, so the part draws 30 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 3 of 37 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.