Eaton 15KP220A 220 V 15000 W TVS Diode
Eaton 15KP220A 220 V 15000 W TVS Diode

Eaton 15KP220A 220 V 15000 W TVS Diode

Share
15KP220A: transient voltage suppressor diode, 220 V standoff, 352.5 V clamp, 42.8 A pulse, 15000 W, unidirectional.
    • Product Details
    • Download

    Eaton 15KP220A 220 V 15000 W TVS Diode

    15KP220A at a glance: transient voltage suppressor diode, 220 V standoff, 352.5 V clamp, 42.8 A pulse, 15000 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number15KP220A
    Standoff voltage (VR)220 V
    Leakage current at VR2 uA
    Breakdown voltage at IT246 V to 272 V
    Test current (IT)5 mA
    Clamping voltage at IPP352.5 V
    Peak pulse current42.8 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    The Figures Explained

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.57 percent, from 246 V to 272 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 220 V standing the leakage is at most 2 uA, so the part draws 0.44 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 34 of 37 in the Eaton catalogue.

    What This Family Is For

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.