Eaton 15KP26CA TVS Diode, 44 V Clamp
Eaton 15KP26CA TVS Diode, 44 V Clamp

Eaton 15KP26CA TVS Diode, 44 V Clamp

Share
15KP26CA: transient voltage suppressor diode, 26 V standoff, 44 V clamp, 343.2 A pulse, 15000 W, bidirectional.
    • Product Details
    • Download

    Eaton 15KP26CA TVS Diode, 44 V Clamp

    15KP26CA at a glance: transient voltage suppressor diode, 26 V standoff, 44 V clamp, 343.2 A pulse, 15000 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number15KP26CA
    Standoff voltage (VR)26 V
    Leakage current at VR50 uA
    Breakdown voltage at IT28.9 V to 31.9 V
    Test current (IT)5 mA
    Clamping voltage at IPP44 V
    Peak pulse current343.2 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.38 percent, from 28.9 V to 31.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 26 V standing the leakage is at most 50 uA, so the part draws 1.3 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 6 of 37 in the Eaton catalogue.

    What This Family Is For

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.