Eaton 15KP30A 30 V 15000 W TVS Diode
Eaton 15KP30A 30 V 15000 W TVS Diode

Eaton 15KP30A 30 V 15000 W TVS Diode

Share
15KP30A: transient voltage suppressor diode, 30 V standoff, 50.7 V clamp, 297.8 A pulse, 15000 W, unidirectional.
    • Product Details
    • Download

    Eaton 15KP30A 30 V 15000 W TVS Diode

    15KP30A at a glance: transient voltage suppressor diode, 30 V standoff, 50.7 V clamp, 297.8 A pulse, 15000 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part number15KP30A
    Standoff voltage (VR)30 V
    Leakage current at VR15 uA
    Breakdown voltage at IT33.3 V to 36.8 V
    Test current (IT)5 mA
    Clamping voltage at IPP50.7 V
    Peak pulse current297.8 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    What the Numbers Mean

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.51 percent, from 33.3 V to 36.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 30 V standing the leakage is at most 15 uA, so the part draws 0.45 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 8 of 37 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.