Eaton 15KP43A 43 V 15000 W TVS Diode
Eaton 15KP43A 43 V 15000 W TVS Diode

Eaton 15KP43A 43 V 15000 W TVS Diode

Share
15KP43A: transient voltage suppressor diode, 43 V standoff, 69.8 V clamp, 216.3 A pulse, 15000 W, unidirectional.
    • Product Details
    • Download

    Eaton 15KP43A 43 V 15000 W TVS Diode

    15KP43A at a glance: transient voltage suppressor diode, 43 V standoff, 69.8 V clamp, 216.3 A pulse, 15000 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part number15KP43A
    Standoff voltage (VR)43 V
    Leakage current at VR2 uA
    Breakdown voltage at IT47.8 V to 52.8 V
    Test current (IT)5 mA
    Clamping voltage at IPP69.8 V
    Peak pulse current216.3 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.46 percent, from 47.8 V to 52.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 43 V standing the leakage is at most 2 uA, so the part draws 0.086 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 12 of 37 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products