Eaton 15KP45A Unidirectional TVS Diode P600 axial
Eaton 15KP45A Unidirectional TVS Diode P600 axial

Eaton 15KP45A Unidirectional TVS Diode P600 axial

Share
15KP45A: transient voltage suppressor diode, 45 V standoff, 72.8 V clamp, 207.4 A pulse, 15000 W, unidirectional.
    • Product Details
    • Download

    Eaton 15KP45A Unidirectional TVS Diode P600 axial

    15KP45A at a glance: transient voltage suppressor diode, 45 V standoff, 72.8 V clamp, 207.4 A pulse, 15000 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part number15KP45A
    Standoff voltage (VR)45 V
    Leakage current at VR2 uA
    Breakdown voltage at IT50 V to 55.3 V
    Test current (IT)5 mA
    Clamping voltage at IPP72.8 V
    Peak pulse current207.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.6 percent, from 50 V to 55.3 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 45 V standing the leakage is at most 2 uA, so the part draws 0.09 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 13 of 37 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products