15KP58CA: transient voltage suppressor diode, 58 V standoff, 93.8 V clamp, 161 A pulse, 15000 W, bidirectional.
    • Product Details
    • Download

    Eaton 15KP58CA Transient Voltage Suppressor 58 V

    15KP58CA at a glance: transient voltage suppressor diode, 58 V standoff, 93.8 V clamp, 161 A pulse, 15000 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part number15KP58CA
    Standoff voltage (VR)58 V
    Leakage current at VR2 uA
    Breakdown voltage at IT64.4 V to 71.2 V
    Test current (IT)5 mA
    Clamping voltage at IPP93.8 V
    Peak pulse current161 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.56 percent, from 64.4 V to 71.2 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 58 V standing the leakage is at most 2 uA, so the part draws 0.116 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 17 of 37 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.