15KP64A: transient voltage suppressor diode, 64 V standoff, 104.2 V clamp, 144.9 A pulse, 15000 W, unidirectional.
    • Product Details
    • Download

    Eaton 15KP64A Unidirectional TVS Diode P600 axial

    15KP64A at a glance: transient voltage suppressor diode, 64 V standoff, 104.2 V clamp, 144.9 A pulse, 15000 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number15KP64A
    Standoff voltage (VR)64 V
    Leakage current at VR2 uA
    Breakdown voltage at IT71.1 V to 78.6 V
    Test current (IT)5 mA
    Clamping voltage at IPP104.2 V
    Peak pulse current144.9 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.55 percent, from 71.1 V to 78.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 64 V standing the leakage is at most 2 uA, so the part draws 0.128 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 19 of 37 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd