Eaton 15KP64CA Transient Voltage Suppressor 64 V
Eaton 15KP64CA Transient Voltage Suppressor 64 V

Eaton 15KP64CA Transient Voltage Suppressor 64 V

Share
15KP64CA: transient voltage suppressor diode, 64 V standoff, 104.2 V clamp, 144.9 A pulse, 15000 W, bidirectional.
    • Product Details
    • Download

    Eaton 15KP64CA Transient Voltage Suppressor 64 V

    15KP64CA at a glance: transient voltage suppressor diode, 64 V standoff, 104.2 V clamp, 144.9 A pulse, 15000 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part number15KP64CA
    Standoff voltage (VR)64 V
    Leakage current at VR2 uA
    Breakdown voltage at IT71.1 V to 78.6 V
    Test current (IT)5 mA
    Clamping voltage at IPP104.2 V
    Peak pulse current144.9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.55 percent, from 71.1 V to 78.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 64 V standing the leakage is at most 2 uA, so the part draws 0.128 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 19 of 37 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.