Eaton 15KP70CA TVS Diode, 113.6 V Clamp
Eaton 15KP70CA TVS Diode, 113.6 V Clamp

Eaton 15KP70CA TVS Diode, 113.6 V Clamp

Share
15KP70CA: transient voltage suppressor diode, 70 V standoff, 113.6 V clamp, 132.9 A pulse, 15000 W, bidirectional.
    • Product Details
    • Download

    Eaton 15KP70CA TVS Diode, 113.6 V Clamp

    15KP70CA at a glance: transient voltage suppressor diode, 70 V standoff, 113.6 V clamp, 132.9 A pulse, 15000 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number15KP70CA
    Standoff voltage (VR)70 V
    Leakage current at VR2 uA
    Breakdown voltage at IT77.8 V to 86 V
    Test current (IT)5 mA
    Clamping voltage at IPP113.6 V
    Peak pulse current132.9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    What the Numbers Mean

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.54 percent, from 77.8 V to 86 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 70 V standing the leakage is at most 2 uA, so the part draws 0.14 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 20 of 37 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products