Eaton 15KP78CA TVS Diode, 126.1 V Clamp
Eaton 15KP78CA TVS Diode, 126.1 V Clamp

Eaton 15KP78CA TVS Diode, 126.1 V Clamp

Share
15KP78CA: transient voltage suppressor diode, 78 V standoff, 126.1 V clamp, 119.7 A pulse, 15000 W, bidirectional.
    • Product Details
    • Download

    Eaton 15KP78CA TVS Diode, 126.1 V Clamp

    15KP78CA at a glance: transient voltage suppressor diode, 78 V standoff, 126.1 V clamp, 119.7 A pulse, 15000 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part number15KP78CA
    Standoff voltage (VR)78 V
    Leakage current at VR2 uA
    Breakdown voltage at IT86.7 V to 95.8 V
    Test current (IT)5 mA
    Clamping voltage at IPP126.1 V
    Peak pulse current119.7 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.5 percent, from 86.7 V to 95.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 78 V standing the leakage is at most 2 uA, so the part draws 0.156 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 22 of 37 in the Eaton catalogue.

    Positioning in the Range

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.