    15KP90CA at a glance: transient voltage suppressor diode, 90 V standoff, 145.6 V clamp, 103.7 A pulse, 15000 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number15KP90CA
    Standoff voltage (VR)90 V
    Leakage current at VR2 uA
    Breakdown voltage at IT100 V to 111 V
    Test current (IT)5 mA
    Clamping voltage at IPP145.6 V
    Peak pulse current103.7 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us15000 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11207

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11207; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 11 percent, from 100 V to 111 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 90 V standing the leakage is at most 2 uA, so the part draws 0.18 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 15KPE family this is item 24 of 37 in the Eaton catalogue.

    Series Positioning

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.