| Parameter | Rating |
|---|---|
| Part number | 3216TD12-R |
| Ordering code | TR/3216TD12-R |
| Packaging | 2,500 pcs on 12 mm tape-and-reel, 180 mm reel, EIA-481-A / IEC 286-3 |
| Design standard | EIA/IS-722 |
| Agency approval | cURus Recognition, File E19180 |
| Voltage rating, DC | 32 Vdc |
| Package | 3.2 x 1.6 mm (1206 imperial / 3216 metric) |
| Interrupting rating | 35 A AC; 35 A DC |
| Typical cold resistance | 0.00425 Ω |
| Rated current | 12 A |
| Typical voltage drop | 79 mV |
| Typical melting I2t | 45.56 A²s |
| Terminations | RoHS compliant, lead-free and halogen-free terminations |
| Voltage rating | 32 Vac |
Common installation contexts include:
Order code 3216TD12-R from Eaton, supplied in 3.2 x 1.6 mm (1206 imperial / 3216 metric). Confirm the exact suffix before release.
What are the ratings of the 3216TD12-R?
12 A continuous at 32 Vdc, interrupting rating 35 A AC; 35 A DC.
Is the 3216TD12-R fast-acting or time-delay?
It is slow-blow. It tolerates short inrush surges.
What size is the 3216TD12-R?
It measures 2 x 1.6 mm. Match the holder or clip to this footprint.
Can the 3216TD12-R be used on a higher fault-current circuit?
No — its interrupting rating is 35 A AC; 35 A DC. Choose a part whose breaking capacity exceeds the prospective fault current.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd