Eaton 3216TD12-R 12 A Slow-Blow 3.2 x 1.6 mm Ceramic Fuse
Eaton 3216TD12-R 12 A Slow-Blow 3.2 x 1.6 mm Ceramic Fuse

Eaton 3216TD12-R 12 A Slow-Blow 3.2 x 1.6 mm Ceramic Fuse

Share
pEaton 3216TD12-R — 12 A, 32 V, time-delay ceramic cartridge fuse, 3.2 x 1.6 mm, 35 A AC; 35 A DC interrupting./p
    • Product Details
    • Download

    Eaton 3216TD12-R 12 A Slow-Blow 3.2 x 1.6 mm Ceramic Fuse

    The 3216TD12-R from Eaton carries 12 A, rated 32 Vdc, uses a slow-blow element, in a ceramic body, measuring 2 x 1.6 mm.

    Technical Data

    ParameterRating
    Part number3216TD12-R
    Ordering codeTR/3216TD12-R
    Packaging2,500 pcs on 12 mm tape-and-reel, 180 mm reel, EIA-481-A / IEC 286-3
    Design standardEIA/IS-722
    Agency approvalcURus Recognition, File E19180
    Voltage rating, DC32 Vdc
    Package3.2 x 1.6 mm (1206 imperial / 3216 metric)
    Interrupting rating35 A AC; 35 A DC
    Typical cold resistance0.00425 Ω
    Rated current12 A
    Typical voltage drop79 mV
    Typical melting I2t45.56 A²s
    TerminationsRoHS compliant, lead-free and halogen-free terminations
    Voltage rating32 Vac

    Practical Notes

    • Interrupting capability is 35 A AC; 35 A DC — confirm the circuit's prospective fault current stays below this.
    • Ceramic body holds higher breaking capacity than glass at the same footprint.
    • It is the usual choice where prospective fault current is high.
    • Footprint 2 x 1.6 mm — check clip or holder compatibility before substitution.
    • Working voltage must stay at or below 32 Vdc; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 12 A to stop nuisance trips — fix the cause instead.

    Application Scenarios

    Common installation contexts include:

    • EV
    • surge

    Buying Notes

    Order code 3216TD12-R from Eaton, supplied in 3.2 x 1.6 mm (1206 imperial / 3216 metric). Confirm the exact suffix before release.

    Questions and Answers

    What are the ratings of the 3216TD12-R?

    12 A continuous at 32 Vdc, interrupting rating 35 A AC; 35 A DC.

    Is the 3216TD12-R fast-acting or time-delay?

    It is slow-blow. It tolerates short inrush surges.

    What size is the 3216TD12-R?

    It measures 2 x 1.6 mm. Match the holder or clip to this footprint.

    Can the 3216TD12-R be used on a higher fault-current circuit?

    No — its interrupting rating is 35 A AC; 35 A DC. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message