Eaton 5.0SMDJ100A 100 V 5000 W TVS Diode
Eaton 5.0SMDJ100A 100 V 5000 W TVS Diode

Eaton 5.0SMDJ100A 100 V 5000 W TVS Diode

Share
5.0SMDJ100A: transient voltage suppressor diode, 100 V standoff, 162 V clamp, 31 A pulse, 5000 W, unidirectional.
    • Product Details
    • Download

    Eaton 5.0SMDJ100A 100 V 5000 W TVS Diode

    5.0SMDJ100A at a glance: transient voltage suppressor diode, 100 V standoff, 162 V clamp, 31 A pulse, 5000 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number5.0SMDJ100A
    Standoff voltage (VR)100 V
    Leakage current at VR2 uA
    Breakdown voltage at IT111 V to 123 V
    Test current (IT)5 mA
    Clamping voltage at IPP162 V
    Peak pulse current31 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us5000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11204

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11204; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.81 percent, from 111 V to 123 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 100 V standing the leakage is at most 2 uA, so the part draws 0.2 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 5.0SMDJ family this is item 53 of 60 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Shenzhen Gaorunxin Technology Co., Ltd