| Parameter | Value |
|---|---|
| Orderable part number | 5.0SMDJ15CAH |
| Standoff voltage (VR) | 15 V |
| Leakage current at VR | 5 uA |
| Breakdown voltage at IT | 16.7 V to 18.5 V |
| Test current (IT) | 5 mA |
| Clamping voltage at IPP | 24.4 V |
| Peak pulse current | 205 A |
| Polarity | Bidirectional |
| Peak pulse power, 10/1000 us | 5000 W |
| Package | SMC (DO-214AB) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1056 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data ELX1056; the package line above is the
body the part is built in.
The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.
The breakdown window spans 10.78 percent, from 16.7 V to 18.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 15 V standing the leakage is at most 5 uA, so the part draws 0.075 mW on the rail. Small, but it is the number that matters on a battery input.
Within the 5.0SMDJ family this is item 16 of 60 in the Eaton catalogue.
Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.
How much capacitance does it add?
Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.
What happens if the surge exceeds the rating?
The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.
Shenzhen Gaorunxin Technology Co., Ltd