| Parameter | Value |
|---|---|
| Orderable part number | 5.0SMDJ17CA |
| Standoff voltage (VR) | 17 V |
| Leakage current at VR | 2 uA |
| Breakdown voltage at IT | 18.9 V to 20.9 V |
| Test current (IT) | 5 mA |
| Clamping voltage at IPP | 27.6 V |
| Peak pulse current | 181 A |
| Polarity | Bidirectional |
| Peak pulse power, 10/1000 us | 5000 W |
| Package | SMC (DO-214AB) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11204 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11204; the package line above is the
body the part is built in.
The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.
The breakdown window spans 10.58 percent, from 18.9 V to 20.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 17 V standing the leakage is at most 2 uA, so the part draws 0.034 mW on the rail. Small, but it is the number that matters on a battery input.
Within the 5.0SMDJ family this is item 19 of 60 in the Eaton catalogue.
Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.
Why is the clamp voltage higher than the breakdown voltage?
The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd