Eaton 5.0SMDJ20CA TVS Diode, 32.4 V Clamp
Eaton 5.0SMDJ20CA TVS Diode, 32.4 V Clamp

Eaton 5.0SMDJ20CA TVS Diode, 32.4 V Clamp

Share
5.0SMDJ20CA: transient voltage suppressor diode, 20 V standoff, 32.4 V clamp, 154 A pulse, 5000 W, bidirectional.
    • Product Details
    • Download

    Eaton 5.0SMDJ20CA TVS Diode, 32.4 V Clamp

    5.0SMDJ20CA at a glance: transient voltage suppressor diode, 20 V standoff, 32.4 V clamp, 154 A pulse, 5000 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number5.0SMDJ20CA
    Standoff voltage (VR)20 V
    Leakage current at VR2 uA
    Breakdown voltage at IT22.2 V to 24.5 V
    Test current (IT)5 mA
    Clamping voltage at IPP32.4 V
    Peak pulse current154 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us5000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11204

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11204; the package line above is the
    body the part is built in.

    The Figures Explained

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.36 percent, from 22.2 V to 24.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 20 V standing the leakage is at most 2 uA, so the part draws 0.04 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 5.0SMDJ family this is item 22 of 60 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products