| Parameter | Value |
|---|---|
| Orderable part number | 5.0SMDJ26A |
| Standoff voltage (VR) | 26 V |
| Leakage current at VR | 2 uA |
| Breakdown voltage at IT | 28.9 V to 31.9 V |
| Test current (IT) | 5 mA |
| Clamping voltage at IPP | 42.1 V |
| Peak pulse current | 119 A |
| Polarity | Unidirectional |
| Peak pulse power, 10/1000 us | 5000 W |
| Package | SMC (DO-214AB) |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11204 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11204; the package line above is the
body the part is built in.
The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.
The breakdown window spans 10.38 percent, from 28.9 V to 31.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 26 V standing the leakage is at most 2 uA, so the part draws 0.052 mW on the rail. Small, but it is the number that matters on a battery input.
Within the 5.0SMDJ family this is item 28 of 60 in the Eaton catalogue.
Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.
What happens if the surge exceeds the rating?
The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.
Why is the clamp voltage higher than the breakdown voltage?
The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd