Eaton 5.0SMDJ26CA Transient Voltage Suppressor 26 V
Eaton 5.0SMDJ26CA Transient Voltage Suppressor 26 V

Eaton 5.0SMDJ26CA Transient Voltage Suppressor 26 V

Share
5.0SMDJ26CA: transient voltage suppressor diode, 26 V standoff, 42.1 V clamp, 119 A pulse, 5000 W, bidirectional.
    • Product Details
    • Download

    Eaton 5.0SMDJ26CA Transient Voltage Suppressor 26 V

    5.0SMDJ26CA at a glance: transient voltage suppressor diode, 26 V standoff, 42.1 V clamp, 119 A pulse, 5000 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part number5.0SMDJ26CA
    Standoff voltage (VR)26 V
    Leakage current at VR2 uA
    Breakdown voltage at IT28.9 V to 31.9 V
    Test current (IT)5 mA
    Clamping voltage at IPP42.1 V
    Peak pulse current119 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us5000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11204

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11204; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.38 percent, from 28.9 V to 31.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 26 V standing the leakage is at most 2 uA, so the part draws 0.052 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 5.0SMDJ family this is item 28 of 60 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products