Eaton 5.0SMDJ40AH 40 V 5000 W TVS Diode
Eaton 5.0SMDJ40AH 40 V 5000 W TVS Diode

Eaton 5.0SMDJ40AH 40 V 5000 W TVS Diode

Share
5.0SMDJ40AH: transient voltage suppressor diode, 40 V standoff, 64.5 V clamp, 78 A pulse, 5000 W, unidirectional.
    • Product Details
    • Download

    Eaton 5.0SMDJ40AH 40 V 5000 W TVS Diode

    5.0SMDJ40AH at a glance: transient voltage suppressor diode, 40 V standoff, 64.5 V clamp, 78 A pulse, 5000 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part number5.0SMDJ40AH
    Standoff voltage (VR)40 V
    Leakage current at VR5 uA
    Breakdown voltage at IT44.4 V to 49.1 V
    Test current (IT)5 mA
    Clamping voltage at IPP64.5 V
    Peak pulse current78 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us5000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1056

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1056; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.59 percent, from 44.4 V to 49.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 40 V standing the leakage is at most 5 uA, so the part draws 0.2 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 5.0SMDJ family this is item 39 of 60 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products