5.0SMDJ43CAH: transient voltage suppressor diode, 43 V standoff, 69.4 V clamp, 72 A pulse, 5000 W, bidirectional.
    • Product Details
    • Download

    Eaton 5.0SMDJ43CAH TVS Diode, 69.4 V Clamp

    5.0SMDJ43CAH at a glance: transient voltage suppressor diode, 43 V standoff, 69.4 V clamp, 72 A pulse, 5000 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number5.0SMDJ43CAH
    Standoff voltage (VR)43 V
    Leakage current at VR5 uA
    Breakdown voltage at IT47.8 V to 52.8 V
    Test current (IT)5 mA
    Clamping voltage at IPP69.4 V
    Peak pulse current72 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us5000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1056

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1056; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.46 percent, from 47.8 V to 52.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 43 V standing the leakage is at most 5 uA, so the part draws 0.215 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 5.0SMDJ family this is item 41 of 60 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd