Eaton 6125FA12A 12 A Fast-Blow Fuse, Ceramic, 6.3 x 2.5 mm
Eaton 6125FA12A 12 A Fast-Blow Fuse, Ceramic, 6.3 x 2.5 mm

Eaton 6125FA12A 12 A Fast-Blow Fuse, Ceramic, 6.3 x 2.5 mm

Share
pEaton 6125FA12A — 12 A, 125 V, fast-acting ceramic cartridge fuse, 6.3 x 2.5 mm, 50 A at 125 Vac; 10,000 A at 86 Vdc interrupting./p
    • Product Details
    • Download

    Eaton 6125FA12A 12 A Fast-Blow Fuse, Ceramic, 6.3 x 2.5 mm

    The 6125FA12A from Eaton carries 12 A, rated 125 Vac / 86 Vdc, uses a fast-acting element, in a ceramic body, measuring 3 x 2.5 mm.

    Technical Data

    ParameterRating
    Part number6125FA12A
    Ordering codeTR2/6125FA12A
    Packaging5,000 pcs on 12 mm tape-and-reel, 13 in (330 mm) reel, EIA-481
    Typical cold resistance0.006 Ω
    Rated current12 A
    Design standardEIA/IS-722
    Package6.3 x 2.5 mm (2410 imperial / 6125 metric)
    Terminationsnickel/silver plated end terminations, solder immersion compatible
    Agency approvalCSA component acceptance 053787 C 000, Class 1422-30; UL Recognition Guide JDYX2, File E19180
    Voltage rating125 Vac / 86 Vdc
    Typical melting I2t69 A²s
    Interrupting rating50 A at 125 Vac; 10,000 A at 86 Vdc
    Typical voltage drop0.103 V

    Practical Notes

    • Interrupting capability is 50 A at 125 Vac; 10,000 A at 86 Vdc — confirm the circuit's prospective fault current stays below this.
    • Fast element suits resistive and semiconductor loads rather than motors with high inrush.
    • Because it opens within milliseconds, downstream semiconductors see less let-through energy.
    • Ceramic body holds higher breaking capacity than glass at the same footprint.
    • It is the usual choice where prospective fault current is high.
    • Footprint 3 x 2.5 mm — check clip or holder compatibility before substitution.
    • Working voltage must stay at or below 125 Vac / 86 Vdc; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 12 A to stop nuisance trips — fix the cause instead.

    Application Scenarios

    Common installation contexts include:

    • EV
    • surge

    Buying Notes

    Order code 6125FA12A from Eaton, supplied in 6.3 x 2.5 mm (2410 imperial / 6125 metric). Confirm the exact suffix before release.

    Questions and Answers

    What are the ratings of the 6125FA12A?

    12 A continuous at 125 Vac / 86 Vdc, interrupting rating 50 A at 125 Vac; 10,000 A at 86 Vdc.

    Is the 6125FA12A fast-acting or time-delay?

    It is fast-acting. Expect it to open quickly on overload.

    What size is the 6125FA12A?

    It measures 3 x 2.5 mm. Match the holder or clip to this footprint.

    Can the 6125FA12A be used on a higher fault-current circuit?

    No — its interrupting rating is 50 A at 125 Vac; 10,000 A at 86 Vdc. Choose a part whose breaking capacity exceeds the prospective fault current.