Eaton 6125FA4A 4 A Ceramic Fuse 125 Vac, Quick-Blow
Eaton 6125FA4A 4 A Ceramic Fuse 125 Vac, Quick-Blow

Eaton 6125FA4A 4 A Ceramic Fuse 125 Vac, Quick-Blow

Share
pEaton 6125FA4A — 4 A, 125 V, fast-acting ceramic cartridge fuse, 50 A at 125 Vac; 300 A at 125 Vdc; 10,000 A at 86 Vdc interrupting./p
    • Product Details
    • Download

    Eaton 6125FA4A 4 A Ceramic Fuse 125 Vac, Quick-Blow

    Built by Eaton, the 6125FA4A carries 4 A, rated 125 Vac / 125 Vdc / 86 Vdc, in a ceramic body.

    Technical Data

    ParameterRating
    Part number6125FA4A
    Ordering codeTR2/6125FA4A
    Packaging5,000 pcs on 12 mm tape-and-reel, 13 in (330 mm) reel, EIA-481
    Design standardEIA/IS-722
    Terminationsnickel/silver plated end terminations, solder immersion compatible
    Interrupting rating50 A at 125 Vac; 300 A at 125 Vdc; 10,000 A at 86 Vdc
    Typical cold resistance0.022 Ω
    Typical voltage drop0.13 V
    Rated current4 A
    Typical melting I2t4.4 A²s
    Package6.3 x 2.5 mm (2410 imperial / 6125 metric)
    Voltage rating125 Vac / 125 Vdc / 86 Vdc
    Agency approvalCSA component acceptance 053787 C 000, Class 1422-30; UL Recognition Guide JDYX2, File E19180

    Selection Notes

    • Interrupting capability is 50 A at 125 Vac; 300 A at 125 Vdc; 10,000 A at 86 Vdc — confirm the circuit's prospective fault current stays below this.
    • Ceramic body holds higher breaking capacity than glass at the same footprint.
    • It is the usual choice where prospective fault current is high.
    • Working voltage must stay at or below 125 Vac / 125 Vdc / 86 Vdc; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 4 A to stop nuisance trips — fix the cause instead.

    Typical Applications

    Engineers usually specify it for these duties:

    • EV

    Part Number and Packing

    Order code 6125FA4A from Eaton, supplied in 6.3 x 2.5 mm (2410 imperial / 6125 metric). Confirm the exact suffix before release.

    Q&A

    What are the ratings of the 6125FA4A?

    4 A continuous at 125 Vac / 125 Vdc / 86 Vdc, interrupting rating 50 A at 125 Vac; 300 A at 125 Vdc; 10,000 A at 86 Vdc.

    Can the 6125FA4A be used on a higher fault-current circuit?

    No — its interrupting rating is 50 A at 125 Vac; 300 A at 125 Vdc; 10,000 A at 86 Vdc. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd