Eaton 6KP15CAH TVS Diode, 24.4 V Clamp
Eaton 6KP15CAH TVS Diode, 24.4 V Clamp

Eaton 6KP15CAH TVS Diode, 24.4 V Clamp

Share
6KP15CAH: transient voltage suppressor diode, 15 V standoff, 24.4 V clamp, 270.5 A pulse, 6600 W, bidirectional.
    • Product Details
    • Download

    Eaton 6KP15CAH TVS Diode, 24.4 V Clamp

    6KP15CAH at a glance: transient voltage suppressor diode, 15 V standoff, 24.4 V clamp, 270.5 A pulse, 6600 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part number6KP15CAH
    Standoff voltage (VR)15 V
    Leakage current at VR5 uA
    Breakdown voltage at IT16.7 V to 18.5 V
    Test current (IT)5 mA
    Clamping voltage at IPP24.4 V
    Peak pulse current270.5 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us6600 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1057

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1057; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.78 percent, from 16.7 V to 18.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 15 V standing the leakage is at most 5 uA, so the part draws 0.075 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 6KPE family this is item 1 of 13 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.