Eaton 6KP16CAH Transient Voltage Suppressor 16 V
Eaton 6KP16CAH Transient Voltage Suppressor 16 V

Eaton 6KP16CAH Transient Voltage Suppressor 16 V

Share
6KP16CAH: transient voltage suppressor diode, 16 V standoff, 26 V clamp, 253.8 A pulse, 6600 W, bidirectional.
    • Product Details
    • Download

    Eaton 6KP16CAH Transient Voltage Suppressor 16 V

    6KP16CAH at a glance: transient voltage suppressor diode, 16 V standoff, 26 V clamp, 253.8 A pulse, 6600 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part number6KP16CAH
    Standoff voltage (VR)16 V
    Leakage current at VR5 uA
    Breakdown voltage at IT17.8 V to 19.7 V
    Test current (IT)5 mA
    Clamping voltage at IPP26 V
    Peak pulse current253.8 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us6600 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1057

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1057; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.67 percent, from 17.8 V to 19.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 16 V standing the leakage is at most 5 uA, so the part draws 0.08 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 6KPE family this is item 2 of 13 in the Eaton catalogue.

    Positioning in the Range

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.