Eaton 6KP18CAH TVS Diode, 29.2 V Clamp
Eaton 6KP18CAH TVS Diode, 29.2 V Clamp

Eaton 6KP18CAH TVS Diode, 29.2 V Clamp

Share
6KP18CAH: transient voltage suppressor diode, 18 V standoff, 29.2 V clamp, 226 A pulse, 6600 W, bidirectional.
    • Product Details
    • Download

    Eaton 6KP18CAH TVS Diode, 29.2 V Clamp

    6KP18CAH at a glance: transient voltage suppressor diode, 18 V standoff, 29.2 V clamp, 226 A pulse, 6600 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part number6KP18CAH
    Standoff voltage (VR)18 V
    Leakage current at VR5 uA
    Breakdown voltage at IT20 V to 22.1 V
    Test current (IT)5 mA
    Clamping voltage at IPP29.2 V
    Peak pulse current226 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us6600 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1057

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1057; the package line above is the
    body the part is built in.

    The Figures Explained

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.5 percent, from 20 V to 22.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 18 V standing the leakage is at most 5 uA, so the part draws 0.09 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 6KPE family this is item 3 of 13 in the Eaton catalogue.

    Series Positioning

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd