Eaton 6KP30AH 30 V 6600 W TVS Diode
Eaton 6KP30AH 30 V 6600 W TVS Diode

Eaton 6KP30AH 30 V 6600 W TVS Diode

Share
6KP30AH: transient voltage suppressor diode, 30 V standoff, 48.4 V clamp, 136.4 A pulse, 6600 W, unidirectional.
    • Product Details
    • Download

    Eaton 6KP30AH 30 V 6600 W TVS Diode

    6KP30AH at a glance: transient voltage suppressor diode, 30 V standoff, 48.4 V clamp, 136.4 A pulse, 6600 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part number6KP30AH
    Standoff voltage (VR)30 V
    Leakage current at VR5 uA
    Breakdown voltage at IT33.3 V to 36.8 V
    Test current (IT)5 mA
    Clamping voltage at IPP48.4 V
    Peak pulse current136.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us6600 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1057

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1057; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.51 percent, from 33.3 V to 36.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 30 V standing the leakage is at most 5 uA, so the part draws 0.15 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 6KPE family this is item 9 of 13 in the Eaton catalogue.

    Positioning in the Range

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products