Eaton 6KP30CAH TVS Diode, 48.4 V Clamp
Eaton 6KP30CAH TVS Diode, 48.4 V Clamp

Eaton 6KP30CAH TVS Diode, 48.4 V Clamp

Share
6KP30CAH: transient voltage suppressor diode, 30 V standoff, 48.4 V clamp, 136.4 A pulse, 6600 W, bidirectional.
    • Product Details
    • Download

    Eaton 6KP30CAH TVS Diode, 48.4 V Clamp

    6KP30CAH at a glance: transient voltage suppressor diode, 30 V standoff, 48.4 V clamp, 136.4 A pulse, 6600 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part number6KP30CAH
    Standoff voltage (VR)30 V
    Leakage current at VR5 uA
    Breakdown voltage at IT33.3 V to 36.8 V
    Test current (IT)5 mA
    Clamping voltage at IPP48.4 V
    Peak pulse current136.4 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us6600 W
    PackageP600 axial
    MountingThrough-hole
    Operating temperature-55 °C to +175 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1057

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1057; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.51 percent, from 33.3 V to 36.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 30 V standing the leakage is at most 5 uA, so the part draws 0.15 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the 6KPE family this is item 9 of 13 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd